Kalstein

Automatic Nucleic Acid Extractor YR01871

SKU:YR01871 · By Kalstein

Category:PCR Thermal Cyclers

Automatic Nucleic Acid Extractor YR01871

Automatic Nucleic Acid Extractor YR01871 — Kalstein laboratory equipment with technical specifications, advanced features, and certified professional solutions for scientific use.

The Automatic Nucleic Acid Extractor YR01871 is an advanced automated system designed to streamline the nucleic acid extraction process. This state-of-the-art extractor utilizes innovative rotary mixing technology to minimize aerosol generation, reducing the risk of cross-contamination and ensuring highly accurate results. Compatible with both deep 96-well plates and six-tube strips, this versatile machine offers high throughput capabilities, enabling the extraction of up to 96 samples per cycle. It features a 7-inch full-color LCD touch screen for effortless operation and incorporates a negative pressure system with HEPA filtration to maintain a biohazard-free environment. Experience unparalleled precision and efficiency with the YR01871 automatic extractor.

Market Price

The market for automated nucleic acid extraction systems sees a variety of pricing depending on specifications and additional features. For a premium product like the YR01871, the price generally ranges between $30,500 and $31,300 USD, reflecting its high-performance capabilities and innovative design. For precise pricing tailored to your needs, we invite you to request a quotation or generate an automatic quote using the Kalstein Plus platform.

Frequently Asked Questions

1. How many samples can be processed per cycle?
The YR01871 can process between 1 to 96 samples in a single cycle, offering great flexibility to suit different experimental needs.

2. What consumables are required?
This system is compatible with 96-deep-well plates and custom 6-strip tubes.

3. What is the warranty period?
Typically, the warranty period for this type of equipment is 1-2 years, depending on the supplier.

Advantages and Disadvantages

Advantages:

  • High throughput with up to 96 samples per cycle.
  • Innovative rotary mixing technology reduces contamination risks.
  • Efficient and quiet operation.

Disadvantages:

  • Initial investment can be considerable for smaller labs.
  • Requires training for optimal operation and maintenance.

Field Usage

In practical applications, the Automatic Nucleic Acid Extractor YR01871 is widely used in research laboratories to streamline and automate the nucleic acid extraction process. This innovation is particularly valuable in high-throughput labs handling numerous samples, where reducing manual handling minimizes the possibility of human error and cross-contamination. Its efficient processing capabilities make it ideal for analyzing clinical, agricultural, and environmental samples, aiding in significant time and resource savings.

Recommendations

To ensure optimal performance, it is recommended to regularly clean and maintain the extractor according to the manufacturer's guidelines. Ensure that operators are adequately trained and familiar with safety and operational protocols. Regularly replacing consumables, such as HEPA filters, is crucial to maintain a contamination-free environment within the system.

Features

  • Automated nucleic acid extraction with rotary mixing technology
  • Capacity of up to 96 samples per cycle
  • 7-inch full-color LCD touch screen for simple operation
  • Negative pressure system with replaceable HEPA filtration
  • Low magnetic bead residue for high accuracy results

Technical Specifications

ModelYR01871
Throughput1-96
Reaction Volume30-1000uL
Sample Volume200uL
Compatible Consumables96-deep-well plates
customized 6 strip tube
Inter-well Extraction DifferenceCV ≤3%
Rotational Speed≤3000rpm
Heating TemperatureLysis heating: room temperature to 120°C
Elution heating: room temperature to 120°C
Mixing MethodRotary mixing
Operation Mode7-inch full-color LCD touch screen operation
Program StorageUp to 1000 programs can be storaged
Protocol ManagementFlexible to create, edit and delete protocols
Automatic ControlMotor-driven automatic opening and closing of the experiment cabinet
Magnetic Bead Residue≤1%
Power Failure ProtectionChoose freely whether or not to continue the experiment when the power is on again after cutting off
Contamination ControlNegative pressure HEPA exhaust filter module;
Built-in UV disinfection module
Connection Port TypeUSB port
Weight45kg (net)
Instrument Dimensions510mm*490mm*480mm (W*L*H)
Power Supply and Power ConsumptionAC 100V-240V, 50/60HZ; 600VA

Technical specifications

Weight54 kg
ManufacturerKalstein

Frequently asked questions

How to know the prices of Automatic Nucleic Acid Extractor YR01871?

To know the price of Automatic Nucleic Acid Extractor YR01871, please send us an email with your request through the contact form AQUI.

What are the delivery times for Automatic Nucleic Acid Extractor YR01871?

Delivery time depends on stock availability and freight type (air or sea). In stock: air 15-30 days, sea 45-60 days. Out of stock: air 30-60 days, sea 60-90 days.

How to make a purchase of Automatic Nucleic Acid Extractor YR01871?

You can buy by email ([email protected]), phone (+33 (0) 1 70 39 26 50) or through the official Kalstein website in your country.

How does the warranty work for Automatic Nucleic Acid Extractor YR01871?

All Kalstein equipment comes with a 1-year warranty against manufacturing defects. The warranty does not cover damage from improper installation or misuse. See our «terms and conditions» AQUI.

Can I request a quote online for Automatic Nucleic Acid Extractor YR01871?

Yes, you can request a quote for the Kalstein equipment you are interested in directly from our official website. Click AQUI.