Kalstein

Automatic Nucleic Acid Extractor YR01869-2

SKU:YR01869-2 · By Kalstein

Category:PCR Thermal Cyclers

Automatic Nucleic Acid Extractor YR01869-2

Automatic Nucleic Acid Extractor YR01869-2 — Kalstein laboratory equipment with technical specifications, advanced features, and certified professional solutions for scientific use.

The Automatic Nucleic Acid Extractor YR01869-2 is a state-of-the-art piece of equipment designed to offer flexibility and efficiency in nucleic acid extraction tasks. Equipped with Rotary Mixing Technology (RMT), this compact and versatile device can handle various flow rates simultaneously and independently, making it ideal for diverse laboratory needs. The extractor’s user-friendly design, which earned the prestigious German Red Dot Design Award 2021, ensures both ease of use and optimal performance. Furthermore, its separate extraction module supports immediate testing across different applications, allowing streamlined, faster testing processes.

Market Price

The market price for automated nucleic acid extractors like the YR01869-2 typically ranges between $8,000 to $9,000 USD. This competitive pricing reflects the advanced features and reliability of the device, ensuring a valuable investment for laboratories and research facilities. For specific pricing details, we encourage you to request a quote.

Frequently Asked Questions

What are the power requirements for the device? The YR01869-2 operates with a power supply of AC220V, 50Hz.

How does the device prevent contamination? It includes UV lamps, internal negative pressure, HEPA filtration, and options to perform operations within a biosafety cabinet.

Is the device easy to transport? Yes, its compact size and mobile power capabilities make it ideal for use in various settings.

Advantages and Disadvantages

The main advantages of the YR01869-2 include its high flexibility, user-friendliness, and robust contamination prevention measures. It supports remote updating and maintenance, which is a great convenience for busy labs. However, potential users should be aware of its initial investment cost and the need for specific consumables, which are customized 96-deep-well plates and single 6-strip tubes.

Field Use

The Automatic Nucleic Acid Extractor YR01869-2 is designed for versatile use. Its mobile power capability allows it to be utilized in various locations, providing reliable nucleic acid extraction for field studies, laboratories, and research sites. The robust temperature control and real-time monitoring features ensure precise and efficient extractions under different conditions.

Recommendations

To maximize the efficiency of the YR01869-2, it is recommended to consistently update its software and protocol settings. Regular maintenance checks and calibrations will keep the machine running smoothly. Additionally, utilizing the device’s app control feature can significantly streamline operations, allowing remote monitoring and management.

Features

  • Flexible performance with rotary mixing technology for multiple flow rates
  • User-friendly interface with touch screen and remote app control
  • Comprehensive contamination prevention measures
  • Automatic protocol recognition and equipment updating
  • Compact design with options for biosafety cabinet operations

Technical Specifications

ModelYR01869-2
Throughput16
Processing Volume20-1700μL
Sample Processing Volume200-500μL
Compatible ConsumablesCustomized 96-deep-well plates, single 6-strip tubes
Inter-well DifferenceCV≤3%
Mixing MethodRotary mixing
Rotary Speed100~3000rpm
Temperature Control RangeTemperature control separately for lysis and elution.
Temperature range from 30°C to 120°C.
Temperature Control AccuracyHeating speed: 4.0±0.2°C/s.
Temperature accuracy: ±1.0°C.
Temperature uniformity:≤1.0°C.
LanguagesChinese/English
Protocol ManagementFlexible to create, edit and delete protocols
Operation ModeMode 1: Android systems in smartphones/tablets
Mode 2: 6.86 inch full-color LCD screen
Automatic ControlAutomatic opening and closing of the experiment cabin
Reagent IdentificationAutomatic identification of reagent information and running the assays
Mixing Sleeve MonitoringReal-time monitoring of the mixing sleeves status in experiment
Magnetic Bead Residue≤1%
Power Failure ProtectionChoose freely whether or not to continue the experiment when the power is on again after cutting off
DisinfectionOzone + UV disinfection
Auto Power-offAuto power-off after UV disinfection
Negative-Pressure FiltrationNegative pressure HEPA filtration module
Connection Port TypeUSB port
Weight7.4Kg (net)
Instrument Dimensions210mm(L)*229mm(W)*242mm(H)
Power SupplyAC220V, 50Hz

Technical specifications

Weight11 kg
ManufacturerKalstein

Frequently asked questions

How to know the prices of Automatic Nucleic Acid Extractor YR01869-2?

To know the price of Automatic Nucleic Acid Extractor YR01869-2, please send us an email with your request through the contact form AQUI.

What are the delivery times for Automatic Nucleic Acid Extractor YR01869-2?

Delivery time depends on stock availability and freight type (air or sea). In stock: air 15-30 days, sea 45-60 days. Out of stock: air 30-60 days, sea 60-90 days.

How to make a purchase of Automatic Nucleic Acid Extractor YR01869-2?

You can buy by email ([email protected]), phone (+33 (0) 1 70 39 26 50) or through the official Kalstein website in your country.

How does the warranty work for Automatic Nucleic Acid Extractor YR01869-2?

All Kalstein equipment comes with a 1-year warranty against manufacturing defects. The warranty does not cover damage from improper installation or misuse. See our «terms and conditions» AQUI.

Can I request a quote online for Automatic Nucleic Acid Extractor YR01869-2?

Yes, you can request a quote for the Kalstein equipment you are interested in directly from our official website. Click AQUI.