Automatic Nucleic Acid Extractor YR01869-2

FabricanteKalstein

Description

The Automatic Nucleic Acid Extractor YR01869-2 is a state-of-the-art piece of equipment designed to offer flexibility and efficiency in nucleic acid extraction tasks. Equipped with Rotary Mixing Technology (RMT), this compact and versatile device can handle various flow rates simultaneously and independently, making it ideal for diverse laboratory needs. The extractor’s user-friendly design, which earned the prestigious German Red Dot Design Award 2021, ensures both ease of use and optimal performance. Furthermore, its separate extraction module supports immediate testing across different applications, allowing streamlined, faster testing processes.

Market Price

The market price for automated nucleic acid extractors like the YR01869-2 typically ranges between $8,000 to $9,000 USD. This competitive pricing reflects the advanced features and reliability of the device, ensuring a valuable investment for laboratories and research facilities. For specific pricing details, we encourage you to request a quote.

Frequently Asked Questions

What are the power requirements for the device? The YR01869-2 operates with a power supply of AC220V, 50Hz.

How does the device prevent contamination? It includes UV lamps, internal negative pressure, HEPA filtration, and options to perform operations within a biosafety cabinet.

Is the device easy to transport? Yes, its compact size and mobile power capabilities make it ideal for use in various settings.

Advantages and Disadvantages

The main advantages of the YR01869-2 include its high flexibility, user-friendliness, and robust contamination prevention measures. It supports remote updating and maintenance, which is a great convenience for busy labs. However, potential users should be aware of its initial investment cost and the need for specific consumables, which are customized 96-deep-well plates and single 6-strip tubes.

Field Use

The Automatic Nucleic Acid Extractor YR01869-2 is designed for versatile use. Its mobile power capability allows it to be utilized in various locations, providing reliable nucleic acid extraction for field studies, laboratories, and research sites. The robust temperature control and real-time monitoring features ensure precise and efficient extractions under different conditions.

Recommendations

To maximize the efficiency of the YR01869-2, it is recommended to consistently update its software and protocol settings. Regular maintenance checks and calibrations will keep the machine running smoothly. Additionally, utilizing the device’s app control feature can significantly streamline operations, allowing remote monitoring and management.

Features

  • Flexible performance with rotary mixing technology for multiple flow rates
  • User-friendly interface with touch screen and remote app control
  • Comprehensive contamination prevention measures
  • Automatic protocol recognition and equipment updating
  • Compact design with options for biosafety cabinet operations

Technical Specifications

Model YR01869-2
Throughput 16
Processing Volume 20-1700μL
Sample Processing Volume 200-500μL
Compatible Consumables Customized 96-deep-well plates, single 6-strip tubes
Inter-well Difference CV≤3%
Mixing Method Rotary mixing
Rotary Speed 100~3000rpm
Temperature Control Range Temperature control separately for lysis and elution.
Temperature range from 30°C to 120°C.
Temperature Control Accuracy Heating speed: 4.0±0.2°C/s.
Temperature accuracy: ±1.0°C.
Temperature uniformity:≤1.0°C.
Languages Chinese/English
Protocol Management Flexible to create, edit and delete protocols
Operation Mode Mode 1: Android systems in smartphones/tablets
Mode 2: 6.86 inch full-color LCD screen
Automatic Control Automatic opening and closing of the experiment cabin
Reagent Identification Automatic identification of reagent information and running the assays
Mixing Sleeve Monitoring Real-time monitoring of the mixing sleeves status in experiment
Magnetic Bead Residue ≤1%
Power Failure Protection Choose freely whether or not to continue the experiment when the power is on again after cutting off
Disinfection Ozone + UV disinfection
Auto Power-off Auto power-off after UV disinfection
Negative-Pressure Filtration Negative pressure HEPA filtration module
Connection Port Type USB port
Weight 7.4Kg (net)
Instrument Dimensions 210mm(L)*229mm(W)*242mm(H)
Power Supply AC220V, 50Hz

Additional information

Weight 11 kg

Quote List

Quote List

No products in the list

Product categories

FAQ

Do you need help?

If you have any questions before processing the order, take a look at the most frequently asked questions

Do you want to know the cost of air shipping to your establishment?

Place your address in the payment area and you will automatically see the shipping to your door!

I am an institution; I need to know the price for several units; I would like to know the cost of the maritime freight

Request a custom quote in the contact section once you identify the model.