Kalstein

Understanding the Technical Glossary and Key Terminology of the YR04973 Oil Bath

By Kalstein · Published on:

Category:articulos-de-productos

Understanding the Technical Glossary and Key Terminology of the YR04973 Oil Bath

Dive deep into the essential technical glossary and terminology related to the YR04973 Oil Bath. This guide covers critical concepts that enhance the understand

3D available

Understanding the Technical Glossary and Key Terminology of the YR04973 Oil Bath

The YR04973 Oil Bath is an essential tool in various fields, including bioengineering, medical research, and food processing. Understanding its technical specifications and key terminology is crucial for effective operation. This guide provides an in-depth look at the essential terms and concepts associated with the YR04973 Oil Bath, enabling users to maximize its potential in their specific applications.

Technical Specifications of the YR04973

SpecificationDetails
ModelYR04973
ControllerPID
Voltage220V / 50Hz, 110V / 60Hz
Power (W)1000W
Temperature Range (°C)RT +5 to 250°C
Temperature Resolution0.1 °C
Temperature Fluctuation≤±0.5°C
Accuracy of Division≤±1°C
Timer999 minutes
Recycling DesignOptional
Magnetic StirringOptional
Safety FeaturesOvercurrent protection, over-temperature alarm, mechanical temperature limiter
Chamber Size (mm)300 x 240 x 150
Product Size (mm)390 x 280 x 240
Packaging Size (mm)440 x 330 x 290

Key Terminology Related to the YR04973

A thorough understanding of the terminology associated with the YR04973 Oil Bath is essential for efficient use. Below is a glossary of key terms:

TermDefinition
PID ControllerA control loop feedback mechanism that maintains the desired output temperature.
Temperature FluctuationThe variation in temperature around the set point during operation.
Magnetic StirringA method of mixing that utilizes a rotating magnetic field to stir liquids.
Overcurrent ProtectionA safety feature that prevents excessive current from damaging the equipment.
Over-temperature AlarmA warning system that alerts the user when the temperature exceeds a safe limit.
Mechanical Temperature LimiterA physical device that restricts the maximum temperature to prevent overheating.
Recycling DesignA feature that allows the oil bath to recycle and maintain a stable temperature.
ResolutionThe smallest change in temperature that can be detected by the instrument.
TimerA built-in feature that allows users to set a duration for heating processes.
Chamber SizeThe dimensions of the area where samples are placed for heating.

Applications of the YR04973 in Various Fields

The YR04973 Oil Bath is versatile and applicable in numerous sectors. Here are some of its primary applications:

  • Bioengineering: Used for maintaining consistent temperatures during biochemical reactions.
  • Medical Research: Essential for experiments requiring precise thermal control.
  • Food Processing: Utilized in methods such as pasteurization and cooking processes.
  • Chemical Industry: Employed in reactions that necessitate high temperatures and stable heat distribution.
  • Educational Institutions: A vital tool for teaching practical laboratory techniques in chemistry and biology.

Troubleshooting Common Issues with the YR04973

Ensuring the YR04973 Oil Bath operates smoothly requires familiarity with potential issues. Below is a troubleshooting guide:

SymptomProbable CausesDiagnostic StepsSolutions
Equipment does not power onPower source issues, faulty plugCheck power connection, inspect the plugReplace plug or connect to a different power source
Error code displayedOver-temperature, sensor malfunctionReview error code in manual, check temperature sensorsReset device, replace faulty sensors
Inconsistent temperature readingsCalibration issues, environmental factorsVerify calibration, assess environmental stabilityCalibrate according to the manual, stabilize environment

Frequently Asked Questions

What is the maximum temperature the YR04973 can reach?

The YR04973 Oil Bath can reach a maximum temperature of 250°C, making it suitable for various high-temperature applications.

How often should the YR04973 be calibrated?

Calibration frequency depends on usage; however, it is recommended to calibrate the YR04973 at least once every six months to ensure accurate readings.

Can the YR04973 be used with both water and oil?

Yes, the YR04973 is designed for dual use with water and oil, providing versatility in temperature control and reactions.

What safety features are included in the YR04973?

The YR04973 includes overcurrent protection, an over-temperature alarm, and a mechanical temperature limiter to ensure safe operation.

Is there an optional stirring feature for the YR04973?

Yes, the YR04973 has an optional magnetic stirring feature, which can enhance mixing during high-temperature reactions.

What should I do if the YR04973 displays an error code?

If an error code is displayed, refer to the user manual for specific troubleshooting steps and solutions related to that code.

How can I request a quote for the YR04973?

You can easily request a quote for the YR04973 Oil Bath through our designated channels, ensuring you receive the best pricing available.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of Oil bath YR04973 with all specifications, dimensions, accessories and quote options.
View product datasheet →